| Version 38 (modified by , 9 years ago) ( diff ) | 
|---|
AmariSoft LTE
Prerequisites
This tutorial series assumes you have an ORBIT account, have scheduled a session on the ORBIT testbed, are familiar with SSH'ing into the testbed itself, and are familiar with the basics of running ORBIT experiments. If you have not done these things yet, you may wish to do so before taking a look at this slightly more advanced experiment. If you are unfamiliar with or are entirely new to ORBIT, you may wish to start here.
Imaging
The image used for this experiment is 'baseline.ndz'. In this tutorial we will use nodes equipped with Netgear AC341u LTE dongles. The basestation is Amarisoft running on Bsc03out.
During a normal experiment using OMF, the following actions are scripted and automated. This is a look at the steps involved in something as simple as starting an LTE connection behind the scenes.
You will run the following commands on node7-1, node1-7, and node19-3 in the Grid.
After connecting to the grid console:
omf load -i baseline.ndz -t node7-1.grid.orbit-lab.orgomf tell -a on -t node7-1.grid.orbit-lab.org- It will take roughly 60 seconds to come up.
 
ssh root@node7-1.grid.orbit-lab.org
Commands on the node
By Default Orbit nodes do not configure any wireless devices. The following 2 are the drivers for the Sierra wireless Netgear LTE dongle 
modprobe GobiSerialmodprobe GobiNetminicom -D /dev/ttyUSB1AT!ippassthrough?- It should return 1
 - If it does not, run the following commands:
AT!ippassthrough=1AT!entercnd="A710"AT!dxcfg=profile,Autoconnect,NeverAT!reset
 
AT!entercnd="A710"- You should see 
OK 
- You should see 
 AT!dxcfg=wwan,connect,11- You should see 
OKthen$QCRMCALL: 1, V4 
- You should see 
 at!gstatus?- Will return a status like: 
at!gstatus? !GSTATUS: Current Time: 10049 Temperature: 42 Bootup Time: 0 Mode: ONLINE System mode: LTE PS state: Attached LTE band: B25 LTE bw: 10 MHz LTE Rx chan: 8365 LTE Tx chan: 26365 EMM state: Registered Normal Service RRC state: RRC Connected IMS reg state: No Srv RSSI (dBm): -83 Tx Power: 0 RSRP (dBm): -117 TAC: 0001 (1) RSRQ (dB): -10 Cell ID: 01A2D001 (27447297) SINR (dB): 1.6
 
- Will return a status like: 
 - Exit Minicom by PRESSING 
Ctrl+A followed by x, thenenterto select ok. dhcpcd eth2followed byenterto get a new line.- You should get an address in the 192.168.3.0/24 subnet.
 
ping 192.168.3.1- You have successfully communicated with the basestation.
 - You can cancel the ping with 
Ctrl+C 
- Attempt running iperf between your nodes.