Changes between Version 11 and Version 12 of Internal/NodeFailureModes


Ignore:
Timestamp:
Feb 19, 2009, 10:38:31 PM (15 years ago)
Author:
ssugrim
Comment:

Legend:

Unmodified
Added
Removed
Modified
  • Internal/NodeFailureModes

    v11 v12  
    1717|| [9,11] ||Disk Failure || Disk Write errors [[BR]] Disk replaced ||
    1818|| [3,19] ||Bad Node || Mother board Failure, refused to boot [[BR]] Replaced ||
     19|| [14,8] ||Disk Failure || Kernel Throws Disk Errors [[BR]] Disk Changed||
     20|| [17,9] ||Disk Failure || Disk write halts, imaging times out[[BR]] Disk replaced ||
     21|| [18,3] ||Over heat || CM measures internal temp at 106F, fails to boot reliably ||
     22|| [20,2] ||Disk Failure || Disk Write errors [[BR]] Disk replaced ||
     23|| [8,13] ||Disk Failure || Disk Write errors [[BR]] Disk replaced ||
     24|| [9,10] ||Disk Failure || Disk Write errors [[BR]] Disk replaced ||
     25|| [5,2] ||Disk Failure || Disk Write errors [[BR]] Disk replaced ||
     26|| [17,13] ||Disk Failure || Disk Write errors [[BR]] Disk replaced ||
     27|| [12,1] ||Disk Failure || Disk Write errors [[BR]] Disk replaced ||
     28|| [6,14] ||Disk Failure || Disk Write errors [[BR]] Disk replaced ||
     29|| [17,19] || Memory Failure || Memory Pins did not make proper contact, Bent case and reinserted memory ||
     30|| [7,2] ||Disk Failure || Disk Write errors [[BR]] Disk replaced ||
     31|| [5,15] ||Lock Up || Rabbit and Node were halted, node ID box LED was solid [[BR]] Power cycled||
     32|| [7,2] ||Lock Up || Rabbit and Node were halted, node ID box led was off [[BR]] Power cycled||
     33|| [16,1] ||Lock Up || Rabbit and Node were halted [[BR]] Power cycled||
    1934
    2035
    21