Sanbox Switch
Each two-node sanbox has a 16 port Netgear GS716T Gigabit Smart Switch with the FQDN of sw-sbXX.orbit-lab.org (where XX is sanbox number 01-09). FOr each of the switches ports 1-4 are reserved for CM subnet, ports 5-8 for sanbox control subnet while ports 9-12 are reserved for sanbox data subnet. Ports 13-15 are assigned to network managemtn while port 16 is, as in the case of other Orbit switches, used for uplink.
Switch Configuration
After configuration check VLANs setup by looking at the switch status and make sure that looks something like this (example is for sanbox 1 → sw-sb01):
IEEE 802.1Q PVID Table
Port | PVID | Port | PVID | Port | PVID | Port | PVID |
01 | 3 | 02 | 3 | 03 | 3 | 04 | 3 |
05 | 11 | 06 | 11 | 07 | 11 | 08 | 11 |
09 | 12 | 10 | 12 | 11 | 12 | 12 | 12 |
13 | 1 | 14 | 1 | 15 | 1 | 16 | 1 |
IEEE 802.1Q VLAN Settings
VLAN ID | Member Port | |||||||||||||||
01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | |
1 | U U U U | |||||||||||||||
3 | U | U | U | U | T T T T | |||||||||||
11 | U | U | U | U | T | T | T | T | ||||||||
12 | U | U | U | U | T | T | T | T |
Configuration is done under the VLAN entry.
Note: New switch has to be connected to the upstream switches untagged port for SmartWizard to even see it. Once new switch is configured with VLANs the upstream switch port should be configured for propper VLAN trunkning.